Earth Support Corp

Early-access preview · interactive

Explore the foundation, end to end.

Drag the knobs and click through every output — the parsed boring log, a 3D pile in the soil, capacity with its uncertainty band, the budget, the CSI-31 spec, and a buildable DXF — without leaving the page. This preview runs a sample Boston boring; live PDF upload arrives with early access.

Recommended element

7-inch micropile, rock-socketed

Shallow competent bedrock favours a small-diameter, rock-socketed micropile installable in low headroom.

Exploring sample boring B-1 · Seaport Tower — preliminary foundation screening. Live PDF upload arrives with early access.

Allowable / element
108 kips
P10–P90 66.5–149.5
Group total
648 kips
6 elements
Embedment
93 ft
7-inch micropile, rock-socketed
Budgetary cost
$172,047
incl. 15% contingency

What-if · allowable capacity

108 kipsper element

Borehole log

Borehole log

B-1Seaport Tower — preliminary foundation screening

100 ft explored

Soil stratigraphy for B-1: 5 layers to 100 feet, groundwater at 10 feet, with 7-inch micropile, rock-socketed embedded to 93 feet.020406080100Depth · ftFILLFillGranular FILL — brown sand, gravel, brick, ash; loose to medium denseOLOrganic silt/clay (L)ORGANIC silt (OL) — soft, dark grey, trace peat (former tidal flat)CLLean clayBoston Blue CLAY (CL) — grey marine clay, soft near top stiffening with depthTILLGlacial tillGlacial TILL — very dense grey silty sand with gravel and cobblesROCKBedrockCambridge ARGILLITE — grey, fresh to slightly weathered, RQD 70–85%SPT · N711246978100100GWT 10Grade
7-inch micropile, rock-socketedtip 93′ · ⌀ 0.60

Hover a stratum for its parameters. Preliminary design-assist — requires PE review and stamp.

Capacity vs depth

Allowable capacity vs depth

Preliminary
Allowable capacity versus depth for the recommended foundation elementDepth increases downward on the vertical axis; allowable capacity in kips runs along the horizontal axis. The shaded region is the P10 to P90 uncertainty band, the solid line is the P50 median, and the marker is the design capacity of 108 kips at 93 feet.050100150200250020406080100Allowable capacity (kips)Depth (ft)108 kips @ 93 ft · FS 2.5

NE-calibrated static method (β/α skin + end bearing). Shaded region = P10–P90 uncertainty band (CoV ≈ 0.3); solid line = P50 median. Preliminary design-assist — requires PE review and stamp.

Preliminary design-assist — requires PE review and stamp. Earth Support Corp, or approved equal.

CallStart Quote